{"id":3798,"date":"2026-10-11T05:11:09","date_gmt":"2026-10-11T05:11:09","guid":{"rendered":"https:\/\/newroad.co.il\/beer-lambert-law\/"},"modified":"2026-11-15T03:43:28","modified_gmt":"2026-11-15T03:43:28","slug":"beer-lambert-law","status":"publish","type":"post","link":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/","title":{"rendered":"Beer-Lambert Law: Formula, Limits and Worked Example"},"content":{"rendered":"<p dir=\"ltr\"><strong>The Beer-Lambert law states that absorbance is directly proportional to concentration: A = &epsilon; &middot; l &middot; c, where &epsilon; is the molar absorptivity in L&middot;mol<sup>&minus;1<\/sup>&middot;cm<sup>&minus;1<\/sup>, l is the path length in cm and c is the concentration in mol\/L. Measure the absorbance of a sample against a blank in a 10 mm cuvette and you can calculate its concentration in seconds, as long as the solution is dilute and the light is close to monochromatic. This guide gives the formula, a worked calculation, the conditions where the law fails, and what to look for in a <a href=\"https:\/\/newroad.co.il\/technologies\/spectroscopy\/\">spectroscopy<\/a> instrument that applies it.<\/strong><\/p>\n<div class=\"nr-takeaways\" style=\"background:#f5f9fc;border-left:4px solid #1d95f1;padding:18px 22px;margin:20px 0;border-radius:6px;\">\n<p dir=\"ltr\" style=\"margin:0 0 8px;font-weight:600;color:#294281;\">Key takeaways<\/p>\n<ul style=\"margin:0;padding-left:20px;\">\n<li>A = &epsilon; &middot; l &middot; c: doubling the concentration or the path length doubles the absorbance.<\/li>\n<li>Absorbance is logarithmic, A = log<sub>10<\/sub>(I<sub>0<\/sub>\/I): A = 1 passes 10% of the light, A = 2 passes 1%, A = 3 passes 0.1%.<\/li>\n<li>A worked example: A = 0.450 in a 1.00 cm cuvette with &epsilon; = 15,000 L&middot;mol<sup>&minus;1<\/sup>&middot;cm<sup>&minus;1<\/sup> gives c = 3.0 &times; 10<sup>&minus;5<\/sup> mol\/L, or 30 &micro;M.<\/li>\n<li>Keep readings between roughly A = 0.1 and A = 1 for the most reliable results; above A = 2 only 1% of the light reaches the detector.<\/li>\n<li>The law holds for dilute solutions and narrow-band light, and it breaks down with scattering, fluorescence, stray light and high concentrations.<\/li>\n<\/ul>\n<\/div>\n<div class=\"nr-toc\">\n<h2 dir=\"ltr\">Table of Contents<\/h2>\n<ul>\n<li><a href=\"#what\">What Is the Beer-Lambert Law?<\/a><\/li>\n<li><a href=\"#formula\">How Do You Calculate Concentration with the Beer-Lambert Law?<\/a><\/li>\n<li><a href=\"#limits\">When Does the Beer-Lambert Law Break Down?<\/a><\/li>\n<li><a href=\"#instrument\">Which Instrument Should You Use to Apply the Law?<\/a><\/li>\n<li><a href=\"#tips\">How Can You Get Reliable Absorbance Readings?<\/a><\/li>\n<li><a href=\"#faq\">Frequently Asked Questions<\/a><\/li>\n<\/ul>\n<\/div>\n<h2 dir=\"ltr\" id=\"what\">What Is the Beer-Lambert Law?<\/h2>\n<p dir=\"ltr\">The Beer-Lambert law (also called Beer&rsquo;s law) is the relationship that makes absorption spectroscopy quantitative. It combines two observations: the fraction of light absorbed depends on the thickness of the sample, which is Lambert&rsquo;s law, and it also depends on the concentration of the absorbing species, which is Beer&rsquo;s law. Absorbance is defined as the base-10 logarithm of the ratio of incident to transmitted light intensity, so the quantity is dimensionless. Not every method detects absorbed light in the optical range: an <a href=\"https:\/\/newroad.co.il\/epr-spectrometer-guide\/\">EPR spectrometer<\/a> measures the absorption of microwaves by unpaired electrons in a magnetic field. Thin films add another optical route: <a href=\"https:\/\/newroad.co.il\/ellipsometry-explained\/\">ellipsometry<\/a> fits a model to changes in polarisation to find film thickness and refractive index.<\/p>\n<p dir=\"ltr\">Written out, the law is <strong>A = &epsilon; &middot; l &middot; c<\/strong>. Every term has a physical meaning, and the three together tell you what you can control in the lab:<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;\">\n<thead>\n<tr style=\"background:#294281;color:#ffffff;\">\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Symbol<\/th>\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Quantity<\/th>\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Usual unit<\/th>\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">What you control<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">A<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Absorbance<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">None (dimensionless)<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Read from the instrument<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">&epsilon;<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Molar absorptivity<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">L&middot;mol<sup>&minus;1<\/sup>&middot;cm<sup>&minus;1<\/sup><\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Fixed for a compound at one wavelength and temperature<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">l<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Path length<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">cm (1.00 cm for a standard cuvette)<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Choose the cuvette or probe<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">c<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Concentration<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">mol\/L<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">What you are solving for<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">I<sub>0<\/sub>, I<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Incident and transmitted intensity<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Counts or power<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Measured against a blank<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 dir=\"ltr\">Absorbance versus transmittance<\/h3>\n<p dir=\"ltr\">Instruments detect transmitted light, so absorbance is calculated from transmittance: A = &minus;log<sub>10<\/sub>(T). The table shows why the scale is logarithmic and why very high absorbance values are hard to trust.<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;\">\n<thead>\n<tr style=\"background:#294281;color:#ffffff;\">\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Absorbance (A)<\/th>\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Transmittance (T)<\/th>\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Light reaching the detector<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">0<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">100%<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">All of it<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">0.1<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">79.4%<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">About four fifths<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">0.3<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">50.1%<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">About half<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">1.0<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">10%<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">One tenth<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">2.0<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">1%<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">One hundredth<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">3.0<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">0.1%<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">One thousandth<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p dir=\"ltr\">The values follow directly from T = 10<sup>&minus;A<\/sup>. At A = 3 the detector sees a thousandth of the light, which is why readings above about A = 2 are noisy on most instruments.<\/p>\n<h2 dir=\"ltr\" id=\"formula\">How Do You Calculate Concentration with the Beer-Lambert Law?<\/h2>\n<p dir=\"ltr\">Rearranging the equation gives <strong>c = A \/ (&epsilon; &middot; l)<\/strong>. The steps are the same whether the sample is a dye, a protein or a pharmaceutical standard.<\/p>\n<h3 dir=\"ltr\">Worked example<\/h3>\n<p dir=\"ltr\">Suppose a dye has a molar absorptivity of 15,000 L&middot;mol<sup>&minus;1<\/sup>&middot;cm<sup>&minus;1<\/sup> at its absorption maximum (an illustrative value, not a specific compound). You measure A = 0.450 in a 1.00 cm cuvette after zeroing on a solvent blank.<\/p>\n<ol>\n<li>Write the equation: c = A \/ (&epsilon; &middot; l).<\/li>\n<li>Substitute: c = 0.450 \/ (15,000 &times; 1.00).<\/li>\n<li>Calculate: c = 3.0 &times; 10<sup>&minus;5<\/sup> mol\/L, which is 30 &micro;M.<\/li>\n<li>If you diluted the sample 1:10 before measuring, multiply by 10: the original solution is 300 &micro;M.<\/li>\n<\/ol>\n<h3 dir=\"ltr\">Calibration curves in practice<\/h3>\n<p dir=\"ltr\">Most laboratories do not rely on a literature &epsilon;. They prepare four to six standards, measure each at the wavelength of maximum absorbance, and fit a straight line through absorbance versus concentration. The slope of that line is &epsilon; &middot; l, so the curve also absorbs small errors in path length and instrument response. Any sample that reads above your highest standard should be diluted rather than extrapolated.<\/p>\n<h2 dir=\"ltr\" id=\"limits\">When Does the Beer-Lambert Law Break Down?<\/h2>\n<p dir=\"ltr\">The law is an ideal. Real measurements deviate for chemical and instrumental reasons, and knowing which one applies saves hours of troubleshooting.<\/p>\n<h3 dir=\"ltr\">Chemical deviations<\/h3>\n<p dir=\"ltr\">At high concentration, molecules interact with each other and the refractive index of the solution changes, so absorbance stops rising in proportion to concentration. Association, dissociation and pH-dependent equilibria change the absorbing species itself. A solution that scatters light, such as a suspension or turbid sample, removes light by a mechanism that is not absorption, so the apparent absorbance is too high.<\/p>\n<h3 dir=\"ltr\">Instrumental deviations<\/h3>\n<p dir=\"ltr\">The law assumes monochromatic light. A real spectrometer passes a band of wavelengths, and if &epsilon; changes across that band the plot curves. Stray light, meaning light that reaches the detector without passing through the sample path correctly, sets a ceiling on measurable absorbance. A simple calculation shows the effect: with 0.1% stray light, a sample whose true absorbance is 2.0 (1% transmittance) reads 1.96, a 2% error, while a sample whose true absorbance is 3.0 (0.1% transmittance) reads 2.70, a 10% error.<\/p>\n<table style=\"width:100%;border-collapse:collapse;margin:16px 0;\">\n<thead>\n<tr style=\"background:#294281;color:#ffffff;\">\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Source of deviation<\/th>\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Typical symptom<\/th>\n<th style=\"background:#294281;color:#ffffff;padding:10px 12px;text-align:left;border:1px solid #294281;\">Practical fix<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">High concentration<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Calibration curve flattens above A &asymp; 1<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Dilute the sample or use a shorter path length<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Stray light<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Readings plateau at high A<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Stay below A = 2; use a better-baffled optical design<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Scattering or turbidity<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Rising baseline toward short wavelengths<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Filter, centrifuge or use an integrating sphere<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Fluorescence<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Absorbance too low<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Measure at a different wavelength or use a bandpass filter<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Wide spectral bandwidth<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Curved calibration for sharp peaks<\/td>\n<td style=\"padding:10px 12px;border:1px solid #d6e2ee;\">Use a narrower slit or higher optical resolution<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 dir=\"ltr\" id=\"instrument\">Which Instrument Should You Use to Apply the Law?<\/h2>\n<p dir=\"ltr\">Any UV-Vis spectrophotometer applies the law, but the design changes how well. Fiber-optic spectrometers are a good fit when you need flexible sampling, such as dip probes, flow cells or in-line process monitoring, while a conventional cuvette instrument is simplest for routine assays. If you are not sure how the two instrument types differ, read our guide to <a href=\"https:\/\/newroad.co.il\/spectrometer-vs-spectrophotometer\/\">spectrometer vs spectrophotometer<\/a>.<\/p>\n<p dir=\"ltr\">NewRoad supplies StellarNet <a href=\"https:\/\/newroad.co.il\/product\/uv-vis-spectrometers\/\">UV-VIS spectrometers<\/a> in Israel. According to the manufacturer&rsquo;s information on the product page, the BLUE-Wave family covers 200 to 1150 nm in 15 standard models, offers a signal-to-noise ratio of 1000:1 and uses 16-bit electronics in a 1 &times; 3 &times; 5 inch enclosure. The BLACK-Comet family uses concave grating optics for low stray light, covers 190 to 850 nm or 280 to 900 nm, and its thermo-electrically cooled detector upgrade raises signal-to-noise by 60%. Low stray light matters directly for the Beer-Lambert law, because it extends the absorbance range you can trust.<\/p>\n<h3 dir=\"ltr\">What to check on a specification sheet<\/h3>\n<p dir=\"ltr\">Look at the wavelength range, the optical resolution in nanometers, the stray light specification, the signal-to-noise ratio and the path length options of the sampling accessories. Our guide on <a href=\"https:\/\/newroad.co.il\/how-to-read-a-spectrometer-spec-sheet\/\">how to read a spectrometer spec sheet<\/a> explains each of these in plain terms.<\/p>\n<h2 dir=\"ltr\" id=\"tips\">How Can You Get Reliable Absorbance Readings?<\/h2>\n<ul>\n<li>Record a fresh blank with the same solvent and cuvette before every measurement series.<\/li>\n<li>Measure at the absorption maximum, where the curve is flattest and small wavelength errors matter least.<\/li>\n<li>Aim for absorbance between 0.1 and 1.0, and dilute anything above 1.5.<\/li>\n<li>Use quartz cuvettes for UV work, because ordinary glass and most plastics absorb ultraviolet light.<\/li>\n<li>Allow the lamp to warm up for the time the manufacturer specifies before collecting data.<\/li>\n<li>Keep temperature constant, since &epsilon; and the equilibrium of many analytes shift with temperature.<\/li>\n<\/ul>\n<h2 dir=\"ltr\" id=\"faq\">Frequently Asked Questions<\/h2>\n<div class=\"sgo-faq\">\n<div class=\"nr-faq-item\">\n<h3 dir=\"ltr\">What is the Beer-Lambert law in simple terms?<\/h3>\n<p dir=\"ltr\">It says that the more concentrated a solution is, or the longer the light travels through it, the more light it absorbs, in direct proportion. The formula is A = &epsilon; &middot; l &middot; c.<\/p>\n<\/div>\n<div class=\"nr-faq-item\">\n<h3 dir=\"ltr\">What are the units of molar absorptivity?<\/h3>\n<p dir=\"ltr\">Molar absorptivity is expressed in L&middot;mol<sup>&minus;1<\/sup>&middot;cm<sup>&minus;1<\/sup> when concentration is in mol\/L and path length is in cm. Absorbance itself has no units.<\/p>\n<\/div>\n<div class=\"nr-faq-item\">\n<h3 dir=\"ltr\">Why is the Beer-Lambert law only valid for dilute solutions?<\/h3>\n<p dir=\"ltr\">At high concentration, molecules interact and the refractive index changes, so absorbance no longer rises in proportion to concentration. Many assays therefore keep absorbance below about 1.<\/p>\n<\/div>\n<div class=\"nr-faq-item\">\n<h3 dir=\"ltr\">What absorbance range is best for quantitative work?<\/h3>\n<p dir=\"ltr\">Readings between roughly A = 0.1 and A = 1.0 are the most reliable, because noise dominates at very low values and stray light dominates above A = 2.<\/p>\n<\/div>\n<div class=\"nr-faq-item\">\n<h3 dir=\"ltr\">Is Beer-Lambert the same as Beer&rsquo;s law?<\/h3>\n<p dir=\"ltr\">Yes. The terms are used interchangeably. Lambert described the dependence on path length, and Beer described the dependence on concentration.<\/p>\n<\/div>\n<div class=\"nr-faq-item\">\n<h3 dir=\"ltr\">Where can I buy a UV-Vis spectrometer in Israel?<\/h3>\n<p dir=\"ltr\">NewRoad supplies StellarNet fiber-optic UV-VIS and NIR spectrometers and HORIBA spectroscopy instruments in Israel, with local support. Contact us to discuss your wavelength range and sampling needs.<\/p>\n<\/div>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the Beer-Lambert law in simple terms?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It says that the more concentrated a solution is, or the longer the light travels through it, the more light it absorbs, in direct proportion. The formula is A = \u03b5 \u00b7 l \u00b7 c.\"}}, {\"@type\": \"Question\", \"name\": \"What are the units of molar absorptivity?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Molar absorptivity is expressed in L\u00b7mol\u22121\u00b7cm\u22121 when concentration is in mol\/L and path length is in cm. Absorbance itself has no units.\"}}, {\"@type\": \"Question\", \"name\": \"Why is the Beer-Lambert law only valid for dilute solutions?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"At high concentration, molecules interact and the refractive index changes, so absorbance no longer rises in proportion to concentration. Many assays therefore keep absorbance below about 1.\"}}, {\"@type\": \"Question\", \"name\": \"What absorbance range is best for quantitative work?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Readings between roughly A = 0.1 and A = 1.0 are the most reliable, because noise dominates at very low values and stray light dominates above A = 2.\"}}, {\"@type\": \"Question\", \"name\": \"Is Beer-Lambert the same as Beer&rsquo;s law?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The terms are used interchangeably. Lambert described the dependence on path length, and Beer described the dependence on concentration.\"}}, {\"@type\": \"Question\", \"name\": \"Where can I buy a UV-Vis spectrometer in Israel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"NewRoad supplies StellarNet fiber-optic UV-VIS and NIR spectrometers and HORIBA spectroscopy instruments in Israel, with local support. Contact us to discuss your wavelength range and sampling needs.\"}}]}\n<\/script><\/p>\n<div class=\"sgo-cta\" style=\"background:#294281;color:#ffffff;padding:28px;border-radius:8px;margin:24px 0;text-align:center;\">\n<p style=\"color:#ffffff;font-size:18px;margin:0 0 14px;\">Need a spectrometer for quantitative absorbance measurements?<\/p>\n<p style=\"margin:0;\"><a href=\"https:\/\/newroad.co.il\/contact\/\" style=\"background:#ffffff;color:#294281;border:2px solid #1d95f1;padding:12px 28px;border-radius:6px;text-decoration:none;font-weight:700;display:inline-block;\">Ask a NewRoad specialist<\/a><\/p>\n<\/div>\n<div class=\"entity-note\" style=\"display:none;\">Entities: NewRoad | Beer-Lambert law | Absorbance | Molar absorptivity | StellarNet BLUE-Wave | StellarNet BLACK-Comet | UV-Vis spectroscopy<\/div>\n<p dir=\"ltr\"><em>Sources: <a href=\"https:\/\/chem.libretexts.org\/Bookshelves\/Physical_and_Theoretical_Chemistry_Textbook_Maps\/Supplemental_Modules_(Physical_and_Theoretical_Chemistry)\/Spectroscopy\/Electronic_Spectroscopy\/Electronic_Spectroscopy_Basics\/The_Beer-Lambert_Law\" rel=\"nofollow noopener\" target=\"_blank\">LibreTexts Chemistry, The Beer-Lambert Law<\/a>; <a href=\"https:\/\/en.wikipedia.org\/wiki\/Beer%E2%80%93Lambert_law\" rel=\"nofollow noopener\" target=\"_blank\">Beer&ndash;Lambert law<\/a>. Instrument figures from the manufacturer&rsquo;s product information (verified October 2026). Worked examples and stray-light figures are illustrative calculations.<\/em><\/p>\n<p dir=\"ltr\"><small>Last updated: October 2026.<\/small><\/p>\n<div class=\"sgo-related\" style=\"background:#f5f9fc;padding:20px 25px;margin:25px 0;border-radius:8px;\">\n<h3 style=\"margin:0 0 12px;color:#294281;\">Related Reading<\/h3>\n<ul style=\"list-style:none;padding:0;margin:0;\">\n<li style=\"padding:5px 0;\"><a href=\"https:\/\/newroad.co.il\/spectrometer-vs-spectrophotometer\/\" style=\"color:#1d95f1;text-decoration:none;\">Spectrometer vs Spectrophotometer: What Each One Measures<\/a><\/li>\n<li style=\"padding:5px 0;\"><a href=\"https:\/\/newroad.co.il\/how-to-read-a-spectrometer-spec-sheet\/\" style=\"color:#1d95f1;text-decoration:none;\">How to Read a Spectrometer Spec Sheet<\/a><\/li>\n<li style=\"padding:5px 0;\"><a href=\"https:\/\/newroad.co.il\/technologies\/spectroscopy\/\" style=\"color:#1d95f1;text-decoration:none;\">UV-Vis-NIR Spectroscopy Instruments<\/a><\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The Beer-Lambert law relates absorbance to concentration. Formula, worked example, limits and instrument choice.<\/p>\n","protected":false},"author":1,"featured_media":3795,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-3798","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Beer-Lambert Law: Formula, Limits and Worked Example<\/title>\n<meta name=\"description\" content=\"Beer-Lambert law links absorbance to concentration: A = \u03b5\u00b7l\u00b7c. See the formula, a worked calculation, where it fails and how to measure it.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/newroad.co.il\/he\/beer-lambert-law\/\" \/>\n<meta property=\"og:locale\" content=\"he_IL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Beer-Lambert Law: Formula, Limits and Worked Example\" \/>\n<meta property=\"og:description\" content=\"Beer-Lambert law links absorbance to concentration: A = \u03b5\u00b7l\u00b7c. See the formula, a worked calculation, where it fails and how to measure it.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/newroad.co.il\/he\/beer-lambert-law\/\" \/>\n<meta property=\"og:site_name\" content=\"NewRoad\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/newroadagencie\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-11T05:11:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-15T03:43:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/10\/nr-beer-lambert-law-AQS4zY.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"1073\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/09\/newroad-share-1200x630.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"\u05e0\u05db\u05ea\u05d1 \u05e2\u05dc \u05d9\u05d3\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u05d6\u05de\u05df \u05e7\u05e8\u05d9\u05d0\u05d4 \u05de\u05d5\u05e2\u05e8\u05da\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 \u05d3\u05e7\u05d5\u05ea\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#\\\/schema\\\/person\\\/1fad1f5628b60179e4661b2dfeb24674\"},\"headline\":\"Beer-Lambert Law: Formula, Limits and Worked Example\",\"datePublished\":\"2026-10-11T05:11:09+00:00\",\"dateModified\":\"2026-11-15T03:43:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/\"},\"wordCount\":1595,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/newroad.co.il\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/nr-beer-lambert-law-AQS4zY.jpg\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"he-IL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/\",\"url\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/\",\"name\":\"Beer-Lambert Law: Formula, Limits and Worked Example\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/newroad.co.il\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/nr-beer-lambert-law-AQS4zY.jpg\",\"datePublished\":\"2026-10-11T05:11:09+00:00\",\"dateModified\":\"2026-11-15T03:43:28+00:00\",\"description\":\"Beer-Lambert law links absorbance to concentration: A = \u03b5\u00b7l\u00b7c. See the formula, a worked calculation, where it fails and how to measure it.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#breadcrumb\"},\"inLanguage\":\"he-IL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"he-IL\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#primaryimage\",\"url\":\"https:\\\/\\\/newroad.co.il\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/nr-beer-lambert-law-AQS4zY.jpg\",\"contentUrl\":\"https:\\\/\\\/newroad.co.il\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/nr-beer-lambert-law-AQS4zY.jpg\",\"width\":1600,\"height\":1073,\"caption\":\"Beer-Lambert law absorbance measurement with a UV-Vis spectrometer and quartz cuvette\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/beer-lambert-law\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u05d3\u05e3 \u05d4\u05d1\u05d9\u05ea\",\"item\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Beer-Lambert Law: Formula, Limits and Worked Example\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#website\",\"url\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/\",\"name\":\"NewRoad\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#organization\"},\"alternateName\":\"\u05e0\u05d9\u05d5 \u05e8\u05d5\u05d0\u05d3 \u05e1\u05d5\u05db\u05e0\u05d5\u05d9\u05d5\u05ea\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"he-IL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#organization\",\"name\":\"NewRoad\",\"url\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"he-IL\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/newroad.co.il\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/newroad-logo.png\",\"contentUrl\":\"https:\\\/\\\/newroad.co.il\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/newroad-logo.png\",\"width\":null,\"height\":null,\"caption\":\"NewRoad\"},\"image\":{\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/newroadagencie\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCdhVlNZY-YAV2bnUz0B5Icg\"],\"alternateName\":[\"\u05e0\u05d9\u05d5 \u05e8\u05d5\u05d0\u05d3\",\"\u05e0\u05d9\u05d5 \u05e8\u05d5\u05d0\u05d3 \u05e1\u05d5\u05db\u05e0\u05d5\u05d9\u05d5\u05ea\",\"NewRoad Agencies\"],\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"4 Oren St.\",\"addressLocality\":\"Shoham\",\"addressCountry\":\"IL\"},\"telephone\":\"+972-3-902-8787\",\"areaServed\":{\"@type\":\"Country\",\"name\":\"Israel\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/#\\\/schema\\\/person\\\/1fad1f5628b60179e4661b2dfeb24674\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"he-IL\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3e3b2bc429d79590065a5d9fd12736718df195224c1c123c8e7f8f5ed23b80f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3e3b2bc429d79590065a5d9fd12736718df195224c1c123c8e7f8f5ed23b80f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c3e3b2bc429d79590065a5d9fd12736718df195224c1c123c8e7f8f5ed23b80f?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/newroad.co.il\"],\"url\":\"https:\\\/\\\/newroad.co.il\\\/he\\\/author\\\/sgo\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Beer-Lambert Law: Formula, Limits and Worked Example","description":"Beer-Lambert law links absorbance to concentration: A = \u03b5\u00b7l\u00b7c. See the formula, a worked calculation, where it fails and how to measure it.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/","og_locale":"he_IL","og_type":"article","og_title":"Beer-Lambert Law: Formula, Limits and Worked Example","og_description":"Beer-Lambert law links absorbance to concentration: A = \u03b5\u00b7l\u00b7c. See the formula, a worked calculation, where it fails and how to measure it.","og_url":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/","og_site_name":"NewRoad","article_publisher":"https:\/\/www.facebook.com\/newroadagencie\/","article_published_time":"2026-10-11T05:11:09+00:00","article_modified_time":"2026-11-15T03:43:28+00:00","og_image":[{"width":1600,"height":1073,"url":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/10\/nr-beer-lambert-law-AQS4zY.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_image":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/09\/newroad-share-1200x630.jpg","twitter_misc":{"\u05e0\u05db\u05ea\u05d1 \u05e2\u05dc \u05d9\u05d3":"admin","\u05d6\u05de\u05df \u05e7\u05e8\u05d9\u05d0\u05d4 \u05de\u05d5\u05e2\u05e8\u05da":"8 \u05d3\u05e7\u05d5\u05ea"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/#article","isPartOf":{"@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/"},"author":{"name":"admin","@id":"https:\/\/newroad.co.il\/he\/#\/schema\/person\/1fad1f5628b60179e4661b2dfeb24674"},"headline":"Beer-Lambert Law: Formula, Limits and Worked Example","datePublished":"2026-10-11T05:11:09+00:00","dateModified":"2026-11-15T03:43:28+00:00","mainEntityOfPage":{"@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/"},"wordCount":1595,"commentCount":0,"publisher":{"@id":"https:\/\/newroad.co.il\/he\/#organization"},"image":{"@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/#primaryimage"},"thumbnailUrl":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/10\/nr-beer-lambert-law-AQS4zY.jpg","articleSection":["Uncategorized"],"inLanguage":"he-IL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/newroad.co.il\/he\/beer-lambert-law\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/","url":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/","name":"Beer-Lambert Law: Formula, Limits and Worked Example","isPartOf":{"@id":"https:\/\/newroad.co.il\/he\/#website"},"primaryImageOfPage":{"@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/#primaryimage"},"image":{"@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/#primaryimage"},"thumbnailUrl":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/10\/nr-beer-lambert-law-AQS4zY.jpg","datePublished":"2026-10-11T05:11:09+00:00","dateModified":"2026-11-15T03:43:28+00:00","description":"Beer-Lambert law links absorbance to concentration: A = \u03b5\u00b7l\u00b7c. See the formula, a worked calculation, where it fails and how to measure it.","breadcrumb":{"@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/#breadcrumb"},"inLanguage":"he-IL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/newroad.co.il\/he\/beer-lambert-law\/"]}]},{"@type":"ImageObject","inLanguage":"he-IL","@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/#primaryimage","url":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/10\/nr-beer-lambert-law-AQS4zY.jpg","contentUrl":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/10\/nr-beer-lambert-law-AQS4zY.jpg","width":1600,"height":1073,"caption":"Beer-Lambert law absorbance measurement with a UV-Vis spectrometer and quartz cuvette"},{"@type":"BreadcrumbList","@id":"https:\/\/newroad.co.il\/he\/beer-lambert-law\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u05d3\u05e3 \u05d4\u05d1\u05d9\u05ea","item":"https:\/\/newroad.co.il\/he\/"},{"@type":"ListItem","position":2,"name":"Beer-Lambert Law: Formula, Limits and Worked Example"}]},{"@type":"WebSite","@id":"https:\/\/newroad.co.il\/he\/#website","url":"https:\/\/newroad.co.il\/he\/","name":"NewRoad","description":"","publisher":{"@id":"https:\/\/newroad.co.il\/he\/#organization"},"alternateName":"\u05e0\u05d9\u05d5 \u05e8\u05d5\u05d0\u05d3 \u05e1\u05d5\u05db\u05e0\u05d5\u05d9\u05d5\u05ea","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/newroad.co.il\/he\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"he-IL"},{"@type":"Organization","@id":"https:\/\/newroad.co.il\/he\/#organization","name":"NewRoad","url":"https:\/\/newroad.co.il\/he\/","logo":{"@type":"ImageObject","inLanguage":"he-IL","@id":"https:\/\/newroad.co.il\/he\/#\/schema\/logo\/image\/","url":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/06\/newroad-logo.png","contentUrl":"https:\/\/newroad.co.il\/wp-content\/uploads\/2026\/06\/newroad-logo.png","width":null,"height":null,"caption":"NewRoad"},"image":{"@id":"https:\/\/newroad.co.il\/he\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/newroadagencie\/","https:\/\/www.youtube.com\/channel\/UCdhVlNZY-YAV2bnUz0B5Icg"],"alternateName":["\u05e0\u05d9\u05d5 \u05e8\u05d5\u05d0\u05d3","\u05e0\u05d9\u05d5 \u05e8\u05d5\u05d0\u05d3 \u05e1\u05d5\u05db\u05e0\u05d5\u05d9\u05d5\u05ea","NewRoad Agencies"],"address":{"@type":"PostalAddress","streetAddress":"4 Oren St.","addressLocality":"Shoham","addressCountry":"IL"},"telephone":"+972-3-902-8787","areaServed":{"@type":"Country","name":"Israel"}},{"@type":"Person","@id":"https:\/\/newroad.co.il\/he\/#\/schema\/person\/1fad1f5628b60179e4661b2dfeb24674","name":"admin","image":{"@type":"ImageObject","inLanguage":"he-IL","@id":"https:\/\/secure.gravatar.com\/avatar\/c3e3b2bc429d79590065a5d9fd12736718df195224c1c123c8e7f8f5ed23b80f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c3e3b2bc429d79590065a5d9fd12736718df195224c1c123c8e7f8f5ed23b80f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c3e3b2bc429d79590065a5d9fd12736718df195224c1c123c8e7f8f5ed23b80f?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/newroad.co.il"],"url":"https:\/\/newroad.co.il\/he\/author\/sgo\/"}]}},"_links":{"self":[{"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/posts\/3798","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/comments?post=3798"}],"version-history":[{"count":0,"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/posts\/3798\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/media\/3795"}],"wp:attachment":[{"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/media?parent=3798"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/categories?post=3798"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/newroad.co.il\/he\/wp-json\/wp\/v2\/tags?post=3798"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}