UV-Vis-NIR spectrometers measure how a sample absorbs, transmits or reflects light across roughly 190-2000 nanometers, giving a spectral fingerprint that identifies chemical compounds and quantifies their concentration.
UV-Vis-NIR spectrometers measure how a sample absorbs, transmits or reflects light across roughly 190-2000 nanometers, giving a spectral fingerprint that identifies chemical compounds and quantifies their concentration.
A light source (deuterium lamp for UV, tungsten-halogen for visible and NIR) illuminates the sample through optical fibers or in a cuvette. The transmitted or reflected light is dispersed by a diffraction grating onto a CCD or InGaAs array detector, generating a spectrum of intensity versus wavelength in milliseconds. In absorbance mode, the spectrum of a sample is compared to a blank reference to calculate absorbance using the Beer-Lambert law. In reflectance mode, the spectrum reveals surface color, gloss and coating properties.
In short: a spectrometer splits light into its wavelengths and measures the intensity at each one, producing a spectrum that identifies a material or shows how much of a substance a sample contains. UV-Vis-NIR instruments pair a deuterium lamp for the UV and a tungsten-halogen lamp for the visible and near-infrared with a diffraction grating and an array detector, so a full spectrum is recorded in milliseconds instead of being scanned one wavelength at a time. The wider family of instruments is outlined in this overview of the spectrometer.
The detector sets the usable range. Silicon CCD and CMOS arrays respond from about 200 nm to 1100 nm, which covers concentration, color and thin-film work. Indium gallium arsenide (InGaAs) arrays respond from about 900 nm to 1700 nm, and extended versions reach roughly 2500 nm, the region used for moisture, fat and protein determination.
| Range | Typical detector | Typical use |
|---|---|---|
| UV-Vis, 190 to 1100 nm | Silicon CCD or CMOS array | Concentration, color, thin-film transmittance |
| Short-wave NIR, 900 to 1700 nm | InGaAs array | Moisture, fat and protein, material sorting |
| Extended NIR, up to about 2500 nm | Extended InGaAs array | Polymers, agricultural products, pharmaceutical blends |
Absorbance follows the Beer-Lambert law only within a limited range: about 1 absorbance unit (AU) on a basic instrument and 2 to 3 AU on a low stray-light design. Above that, the calibration curve bends and the sample needs dilution. Optical resolution of compact fiber-optic spectrometers commonly runs from about 0.1 nm to 10 nm, set by the slit width and the grating. Our guide to reading a spectrometer spec sheet shows which of those numbers matter for your sample.
The terms overlap in practice. A spectrophotometer is built to measure absorbance or transmittance of a sample against a reference, while spectrometer covers any instrument that records a spectrum, including emission, fluorescence and Raman systems. The spectrometer vs spectrophotometer comparison goes through the differences with examples.
Use UV-Vis when you quantify a dissolved compound or measure color and film thickness. Use NIR for bulk moisture, fat and protein without sample preparation, as described in our NIR spectroscopy guide. Use Raman or FTIR when you need molecular identification, compared in Raman vs FTIR, or a handheld Raman spectrometer for checks in the field.
Have four numbers ready: the wavelength range, the optical resolution you need, the absorbance range of your samples and the integration time your process allows. NewRoad supplies NIR spectrometers and UV-VIS spectrometers for research and quality-control labs in Israel. To match an instrument to your samples, request a quote from our applications team.
A spectrometer disperses light into its wavelengths and measures the intensity at each one. The resulting spectrum shows how a sample absorbs, transmits, reflects or emits light, which identifies compounds and quantifies their concentration.
Most systems span roughly 190 to 2000 nm. Silicon detectors cover about 200 to 1100 nm, InGaAs detectors cover about 900 to 1700 nm, and extended InGaAs reaches roughly 2500 nm.
A spectrophotometer measures how much light a sample absorbs or transmits against a reference. A spectrometer is the broader term for any instrument that records a spectrum, including fluorescence, emission and Raman systems.
Choose NIR when you need moisture, fat or protein in solids, powders or liquids with little or no sample preparation. Choose UV-Vis for dissolved compounds that absorb in the 190 to 800 nm region, such as dyes, proteins and active pharmaceutical ingredients.
Typical users are pharmaceutical labs quantifying active ingredients, food and beverage quality control, environmental water and soil analysis, and thin-film and coating research.